| DC VOLTAGE |
11, 33
|
| RATED CURRENT |
1.050
|
| RATED POWER |
34.7
|
| RIPPLE & NOISE |
300mVp-p
|
| VOLTAGE TOLERANCE |
±5.0%
|
| LINE REGULATION |
±1.0%
|
| LOAD REGULATION |
±3.0%
|
| SET UP, RISE TIME |
3000ms, 180ms / 230VAC 3000ms, 150ms / 115VAC at full load
|
| HOLD UP TIME |
20ms/230VAC,15ms/115VAC at full load
|
| VOLTAGE ADJ.RANGE |
90 ~ 264VAC 127 ~ 370VDC
|
| FREQUENCY RANGE |
47 ~ 63Hz
|
| EFFICIENCY |
84%
|
| AC CURRENT |
0.2A/230VAC;0.35A/115VAC
|
| INRUSH CURRENT |
COLD START 70A(twidth=120μs measured at 50% Ipeak) at 230VAC
|
| MAX. NO. OF PSUS ON 16A CIRCUIT BREAKER |
17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC
|
| LEAKAGE CURRENT |
0.25mA / 240VAC
|
| OVER VOLTAGE |
Protection type : Shut off o/p voltage, clamping by zener diode36 ~ 43V
|
| WORKING TEMP |
-30 ~ +70℃(Refer to "Derating Curve")
|
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing
|
| STORAGE TEMP HUMIDITY |
-40 ~ +80℃, 10 ~ 95% RH
|
| TEMP. COEFFICIENT |
±0.2%/℃(0 ~ 50℃)
|
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
| SAFETY STANDARDS |
UL8750,CSA C22.2 No.250.0-08 approved, Design refer to EN60950-1
|
| WITH STAND VOLTAGE |
I/P-O/P:3.75KVAC
|
| ISOLATION RESISTANCE |
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
|
| EMC EMISSION |
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3
|
| EMC IMMUNITY |
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
|
| MTBF |
518.9K hrs min. MIL-HDBK-217F (25℃)
|
| DIMENSION |
84*57*29.5(L*W*H)
|
| PACKING |
0.18Kg; 72pcs / 14Kg/ 0.92CUFT
|